LXSGY Water

LXSG-E is a turbine super dry water meter 

Features

* Magnetic drive, lower transmission resistance, frog-resistant. 

* Magnetic shield, for external magnetic field protection 

* Evacuated and sealed dry dial register ensures clear reading 

* Internal strainer, inlet strainer for selecting 

* The register can be 5 rollers and 4 pointers or 8 rollers and 1 pointer.

Standards Compliance 

Technical data conforms to ISO 4064 Class B, Class C, R80, R100, R125 or R160 standard for horizontal installation.

Optional Features 

*Several lengths and connections available on request 

*Non return Valve 

*Meter body: Brass, plastic, iron and stainless steel for selecting.

* Pre-equipped pulse output (reed switch; hall or non-magnetic metal plate).

Working Conditions 

Water temperature: ≤50ºC for cold water meter

Water temperature: ≤90ºC for hot water meter 

Water pressure: ≤1MPa or 1.6MPa optional (10bar or 16bar optional) 

Installation requirements 

*The meter should be installed in horizontal position with the direction of the flow as indicated by the arrow cast in the meter body with the register face upwards. 

*Pipeline must be flushed before installation. 

*The meter should be constantly full of water during operation. 

Maximum Permissible Error 

In the lower zone from Qmin(Q1) inclusive up to but excluding Qt (Q2) is ±5%. 

In the upper zone from Qt(Q2) inclusive up to and including Qmax(Q4) is ±2%(cold water meter).

In the upper zone from Qt(Q2) inclusive up to and including Qmax (Q4) is ±3% (hot water meter).