IFM KQ Series

 Product characteristics
Capacitive sensor
Rectangular, plastics
Cable with connector
Teach function
Electronic lock
Sensing range 12 mm; [nf] non-flush mountable
 Application
Application   Position sensor and detection of dry bulk materials and liquids through non-metallic tank walls or on bypass pipes
 Electrical data
Electrical design   DC PNP
Operating voltage [V]   10...30 DC
Current consumption [mA]   < 17
Protection class   III
Reverse polarity protection   yes
 Outputs
Output function   normally open / closed programmable
Voltage drop [V]   < 2.5
Current rating [mA]   100
Short-circuit protection   pulsed
Overload protection   yes
Switching frequency [Hz]   10
 Detection range
Sensing range [mm]   12
Real sensing range (Sr) [mm]   12 ± 10 %
 Accuracy / deviations
Hysteresis [% of Sr]   1...15
Switch-point drift [% of Sr]   -20...20
 Interfaces
IO-Link device
Transfer type   COM1 (4.8 kBaud)
IO-Link revision   1.1
SDCI standard   IEC 61131-9 CDV
IO-Link device ID   371d / 000173h
Profiles   Smart Sensor
SIO mode   yes
Process data analogue   -
Min. process cycle time [ms]   100.8
 Environment
Ambient temperature [°C]   -25...80
Protection   IP 65 / IP 67
 Tests / approvals
EMC  
EN 61000-4-2 ESD:  8 kV AD
EN 61000-4-3 HF radiated:  10 V/m
EN 61000-4-4 Burst:  2 kV
EN 61000-4-6 HF conducted:  3 V
EN 55011:  class B
Shock resistance  
EN 60068-2-27: 30 g 6 shocks / 11 ms half-sine (x,y,z)  
Vibration resistance  
EN 60068-2-6: (10...55 Hz) / 1 mm amplitude, oscillation period 5 min., 30 min. per axis at resonance or 55 Hz
MTTF [Years]   725
 Mechanical data
Mounting   non-flush mountable
Housing materials   housing: PBT (glass fiber reinforced); buttons: TPE-U; cover: PC (glass fiber reinforced)
Weight [kg]   0.025
 Displays / operating elements
Output status indication LED   yellow
 Electrical connection
Connection   PVC cable / 0.04 m; with M8 connector
Wiring
4: OUT / IO-Link
 Remarks
Pack quantity [piece]   1